Six procedures.
Procedure 1 — Static system leak test (S1, K19, R5)
Regulated work. Read part 43 appendix E before you start, every time.
- Confirm the test is required and why — interval, or maintenance that disturbed the system.
- Isolate or protect instruments the procedure requires you to.
- Connect the test set to the static ports, sealing them per the procedure.
- Apply vacuum slowly to the specified altitude equivalent — never exceed instrument ranges.
- Hold, and observe the leak rate over the specified time.
- Compare against the tolerance in appendix E.
- Release slowly.
- Record: the test, the method, the result, the date, and the entry under GEN-I Procedures Procedure 6.
Check — read the tolerance out of appendix E and say it before you start. A test whose pass criterion you cannot state is not a test.
Failure — applying pressure to the static system, or vacuum to the pitot. Reversed, it over-ranges the instruments in the direction they cannot take, and all three are damaged with no outward sign (AF-H Concepts §2).
Procedure 2 — Remove and install an instrument (S2)
- De-energize and, where the instrument is pneumatic, isolate the lines.
- Handle gyroscopic instruments as fragile, in packaging, without shock (AF-H Concepts §3).
- Disconnect electrical and pneumatic connections, capping the lines immediately.
- Remove mounting hardware, supporting the instrument.
- Install the replacement: confirm the part number is correct for the aircraft, fit mounting hardware, reconnect, torque per the manual.
- Check the range markings are correct for this aircraft (Procedure 3).
- Check bonding where the installation requires it.
- Functional check, and leak check where the system was opened.
Check — cap every line as it comes off. An open static line collects debris and moisture, and the next leak check will fail for a reason you introduced.
Procedure 3 — Install and check range markings (S3, S5)
- Get the values from the aircraft's TCDS, not from the instrument and not from another aircraft (GEN-I Procedures Procedure 1).
- Confirm the instrument's scale matches the values — the same limitation on a different scale sits in a different place.
- Apply markings by the approved method, on the glass or the dial as specified.
- Apply a slippage mark across the glass and the case.
- Check alignment against the dial.
Check — the slippage mark is the check, and it is permanent. A marking that has rotated is worse than none, because it looks authoritative (AF-H Concepts §5).
Procedure 4 — Inspect a magnetic compass (S6)
- Check the fluid level — a bubble is a finding.
- Check for discoloration, leakage, and card freedom — the card must swing freely and settle.
- Check the compensating screws are secure and the correction card is present, legible and for this aircraft.
- Check mounting security and that no ferrous or magnetic item has been placed nearby.
Check — the correction card must match the aircraft and its current configuration. A card from before an avionics installation is a card for a different magnetic environment.
Procedure 5 — Vacuum system: filter, then regulator (S10, S11)
Order matters (AF-H Concepts §4).
- Inspect the filter first. Replace at the specified interval or if restricted.
- Check the system for leaks — hoses, connections, and instrument case seals.
- Only then measure vacuum at the specified point, with the engine at the specified RPM.
- Adjust the regulator to the specified value.
- Recheck after adjustment, and check gyro erection times.
Check — if you had to move the regulator a long way, ask why. A large adjustment usually means a restriction or a leak that you have just compensated for rather than fixed.
Procedure 6 — Inspect the alternate static source (S12)
- Confirm the selector operates and reaches both positions positively.
- Check the alternate port is clear and correctly located.
- Confirm the placard is present and legible.
- Include the alternate position in the leak check where the procedure requires it.
Check — an alternate static source that has never been tested is not a system, it is a control. It is only useful if it works when the primary is blocked, and that is exactly when nobody will be able to test it.
The checks, collected
| Procedure | The check |
|---|---|
| Static leak test | State the appendix E tolerance before starting |
| Instrument R&I | Cap every line as it comes off |
| Range markings | The slippage mark, and the TCDS values |
| Compass | The correction card matches this aircraft, as configured now |
| Vacuum | Filter first; a large regulator adjustment means a hidden fault |
| Alternate static | Test it, because you cannot when you need it |