Five procedures.
Procedure 1 — Clean a pneumatic deicer boot (S3, R3)
- Identify the approved cleaner from the boot manufacturer's instructions. Nothing else.
- Remove loose dirt with clean water first.
- Apply the cleaner as specified, working gently — no aggressive scrubbing and no abrasives.
- Rinse and dry.
- Apply the approved dressing where the manufacturer specifies one.
- Inspect while you work: cuts, punctures, abrasion, lifting at the bond line, cracking.
Check — name the product before you open it. A general shop solvent will clean the boot and destroy it, and the damage appears weeks later (AF-L Concepts §2).
Procedure 2 — Inspect and operationally check a deicer boot (S2)
- Inspect the boot surface and bond line — lifting at an edge is a finding.
- Check air lines and connections for security and leaks.
- Operate the system and watch: each boot inflates fully, in the correct sequence, and deflates cleanly and completely.
- Time the cycle against the manual.
- Check inflation pressure against the specification.
Check — watch the deflation, not just the inflation. A boot that inflates well and stays partly inflated is a permanent aerodynamic penalty and a sign of a suction or valve fault.
Procedure 3 — Inspect and check an electrically heated system (S1, S5, S6, S7)
- Visual: element condition, connections, security, chafe, discoloration or burning at terminals.
- Measure current with the system on, and compare against the expected value (GEN-A Procedures Procedure 3).
- Or measure element resistance cold, against specification, with the circuit isolated.
- Check the control and any thermostat or overheat protection functions.
- On a heated windshield, check for delamination, discoloration and hot spots.
Check — measure, do not feel. A partially failed element still gets warm, and warmth is not evidence that it is producing its rated heat (AF-L Concepts §4).
Procedure 4 — Troubleshoot a heated pitot circuit (S4)
- Predict: supply voltage, expected current, expected element resistance.
- Confirm supply at the breaker and at the switch.
- Voltage drop under load along the circuit — supply, switch, connector, element, ground.
- The whole supply voltage across a break locates an open; volts across a connection locates resistance.
- Check the ground. It is the most commonly overlooked half of the circuit.
Check — the drops must sum to the supply voltage. If they do not, an element you have not measured holds the missing volts (GEN-A Procedures Procedure 5).
Procedure 5 — Inspect a rain control system (S8, S9)
- Wipers: blade condition, arm pressure, park position, and that the mechanism sweeps the specified area without contacting the frame.
- Chemical systems: fluid level, nozzle condition, spray pattern.
- Bleed-air rain removal: duct and nozzle condition, security.
- Check for anything that could damage the transparency — a worn blade with exposed metal will scratch a windscreen in one pass.
Check — run the wipers dry only if the manual permits it. Dry operation damages both blade and transparency, and it is the fastest way to ruin a windscreen during an inspection.
The checks, collected
| Procedure | The check |
|---|---|
| Boot cleaning | Name the approved product before opening it |
| Boot check | Watch the deflation, not just the inflation |
| Heated systems | Measure current — do not feel for warmth |
| Pitot troubleshooting | Drops must sum to supply; check the ground |
| Rain control | Do not run wipers dry unless the manual permits |