Seven procedures. Procedure 0 is not optional and is not a formality.
Procedure 0 — Relieve and confirm (R1, R2)
- Shut the system down per the manual.
- Relieve pressure by the manual's method. This is usually a specific action, not simply waiting.
- Confirm on a gauge that pressure is zero — including any accumulator, which holds pressure independently of the pump (AF-F Concepts §1).
- Discharge the accumulator's fluid side if you are working on it or downstream of it.
- PPE for the fluid, and containment.
Check — say what the gauge reads, and which gauge. If there is no gauge on the circuit you are opening, you have not confirmed anything.
Failure — opening a component downstream of a charged accumulator. The system is off, the pump is stopped, and the energy is still there.
Procedure 1 — Identify the fluid and the seals (S1, S2, S15)
- Read the placard and the manual for the approved fluid. That is the authority.
- Check what is actually in the container you intend to use — label, color, and whether it has been decanted.
- Confirm the seal material is compatible with that fluid before fitting anything (AF-F Concepts §2).
- Never mix families. If a system's fluid is in doubt, that is a finding.
Check — name the fluid specification, not its color. Color is a cross-check on a correctly labeled container, not an identification.
Failure — topping up from an unlabeled can. The aircraft flies fine, and every seal in the system begins failing weeks later.
Procedure 2 — Install seals and backup rings (S3, S16)
- Confirm the part number of the packing against the component manual, and check its cure date.
- Inspect the groove and the mating surfaces — burrs, scratches and corrosion will cut the seal.
- Protect the seal on entry: thread protectors, installation tools, tape over sharp edges.
- Lubricate with the system fluid unless the manual says otherwise.
- Fit the backup ring on the low-pressure side of the packing — the side away from the pressure it must resist extrusion toward (AF-F Concepts §3).
- Assemble without twisting the packing in its groove.
- Torque per the manual and operationally check.
Check — state which side is the pressure side before fitting the backup ring. If you cannot, you cannot fit it correctly, and it will look fitted either way.
Failure — a nicked seal on installation. It seals on the bench and weeps in service.
Procedure 3 — Service an accumulator (S7)
- Procedure 0 first, and discharge the fluid side completely.
- Check the gas precharge with the fluid side discharged — a precharge read with fluid pressure present is meaningless.
- Compare against the manual's precharge, at the stated temperature.
- Charge with the specified gas — usually dry nitrogen, never oxygen and never shop air.
- Recheck after the charge has stabilized.
- Restore the system and check operation.
Check — the fluid side must be fully discharged before you read the precharge. A reading taken with fluid pressure present tells you about the system, not the accumulator.
Failure — charging with the wrong gas. Compressed air introduces moisture and oxygen; oxygen with hydraulic fluid is a fire.
Procedure 4 — Service a reservoir (S8)
- Check the level in the condition the manual specifies — system pressurized or not, gear and flaps in a stated position, accumulator charged or discharged. The level moves with all of these.
- Clean around the filler before opening.
- Add the approved fluid only, to the specified level.
- Check for leaks and record.
Check — confirm the configuration the level is specified in. A reservoir filled to the mark with the gear up will overflow when the gear comes down.
Procedure 5 — Service a filter (S6)
- Procedure 0.
- Note the bypass indicator before removal — a popped indicator is a finding, and it means unfiltered fluid has been circulating.
- Remove, catching fluid.
- Inspect the element for debris, and identify what you find (PP-G §1 — the same reasoning in oil).
- Fit a new element with new seals, torque per the manual.
- Reset the indicator, restore the system, check for leaks.
Check — look at the element before you throw it away. It is the only evidence you will get about what is happening inside the system, and metal in it is a finding regardless of the indicator.
Procedure 6 — Remove and install a component (S4, S9, S12)
- Procedure 0.
- Cap every line and port as it is opened (GEN-F Procedures Procedure 1).
- Support the component; note the orientation and any shims or clocking.
- Fit new seals per Procedure 2.
- Install, torque per the manual, holding fittings with a second wrench (GEN-D Procedures Procedure 6).
- Operational check: pressurize, check for leaks, check function through full travel or full range.
- Purge air if the system was opened (Procedure 7).
Check — an operational check is part of the installation, not a separate job. A component fitted and not checked is a component you have not finished installing.
Procedure 7 — Purge air (S11)
- Follow the manual's bleeding sequence — order matters, and the highest point or the furthest actuator is usually first.
- Operate the system through full travel repeatedly to move air to the bleed points.
- Bleed until the fluid runs clear and free of bubbles.
- Maintain reservoir level throughout — running it dry draws in more air and you start again.
- Check operation for firmness and consistency.
Check — operate the system several times and confirm the response is consistent. Spongy or varying response means air remains (AF-F Concepts §4).
Failure — letting the reservoir run low during bleeding. It undoes the whole procedure and it is easy to do.
The checks, collected
| Procedure | The check |
|---|---|
| Relieve and confirm | Say what the gauge reads, and which gauge |
| Fluid and seals | Name the specification, not the color |
| Seals and backup rings | State which side is the pressure side |
| Accumulator | Fluid side fully discharged before reading precharge |
| Reservoir | Confirm the configuration the level is specified in |
| Filter | Look at the element before discarding it |
| Component R&I | The operational check is part of the installation |
| Purging | Consistent response over several operations |