Source: FAA-H-8083-31B, fire protection chapter. Public domain. Pointers only.
Chapter and section verified against FAA-H-8083-31B, 2023 edition, on 28 August 2026. Page numbers are deliberately not cited: they move between printings, and a citation that rots silently is worse than a coarser one that stays true. Checked by our handbook citation check against our index of the handbook's chapters and sections.
| Elements | The ACS asks for | Where in FAA-H-8083-31B | Read it for |
|---|---|---|---|
K1, K2, S9, S12, S3 |
Fire types and zones; detection and warning; continuous-loop systems | Ch. 17 — Detectors; Continuous-Loop Systems; Pneumatic Continuous-Loop Systems; Flame Detectors | How a loop actually detects. AF-M Concepts §2 |
K3, S7, S6 |
Detection maintenance and inspection; overheat detectors | Ch. 17 — Detectors; Continuous-Loop Systems | — |
K4, S4, S5 |
Smoke and carbon monoxide detection | Ch. 17 — Smoke Detectors; Smoke Detector System; Carbon Monoxide Detectors; Lavatory Smoke Detector System | The CO path — AF-G Concepts §3 |
K5–K7, S2, S8, S11 |
Agents; extinguishing system types; maintenance | Ch. 17 — Fire Extinguishing Systems; Installed Fire Extinguishing Systems; CO2 Fire Extinguishing Systems; Extinguisher Types; Containers; Fire Extinguisher System Maintenance | Agent classes and their limits |
S8, S11 |
Cylinder hydrostatic dates; discharge cartridge | Ch. 17 — Fire Extinguisher System Maintenance; Containers | AF-M Concepts §3 — time-based airworthiness |
S10 |
Operational check of a detection system | Ch. 17 — Fire Extinguisher System Maintenance | The one station element |
S13 |
Press-to-test, and troubleshooting | Ch. 17 — Fire Extinguisher System Maintenance | What press-to-test actually proves. AF-M Concepts §4 |
R1 |
Squib circuits | Ch. 17 — Containers; Fire Extinguishing Systems | AF-M Concepts §1 — read this first |
R2, R3 |
PPE when testing; extinguishing agents | Ch. 17 — Extinguisher Types | The safety data sheet governs |
The operative sources
- The aircraft maintenance manual's squib safing procedure —
R1. - The bottle manufacturer's data for hydrostatic intervals, cartridge life and charge pressure against temperature.
License
CC BY-SA 4.0 (Licensing).